Maquet iabp workbook pdf

Maquet balloon pump instruction poster catheter syringe. Get the inside scoop on jobs, salaries, top office locations, and ceo insights. Getinge group passion for life, getinge group, getinge, arjohuntleigh and maquet are trademarks or registered trademarks of getinge ab, its subsidiaries. Your atrium sales representatives will be contacting you to assist in completing the cmn form. Maquet cardiovascular llc maquet warrants that reasonable care has been used in the design and. Inflation of the iabp should occur on the dicrotic notch of the arterial waveform. Intraaortic balloon pump troubleshooting litfl curveball. Maquet can look back on 170 years of experience in medical technology and has traditionally acted as a trailblazer with its new products. Quadroxid device modification the only modifi cation consists of adding a reusable stainless steel holding clamp as. Today, that same commitment and experience is being applied to anesthesia, leading to. Generally, balloon pump therapy lasts anywhere from a couple of hours to several days, depending on how much help the heart needs. Together with the two other business areas arjo extended care and getinge infection control, the entire getinge group of companies focuses on forwardlooking medical technology.

The device is introduced from the femoral artery and guided into the aorta till its tip. Maquet cardiosave iabp hybrid maquetspecification sheet. Intraaortic balloon pump counterpulsation iabp for. Tegris is the ideal counterpart to the flexible room system variop, integrating all elements of room ergonomics and workflow.

The maquet brand represents the medical systems business division. Maquet is a subsidiary of the publicly listed swedish getinge group. Clinical support services theory and techniques of iab maquet. Federal usa law restricts this device to sale by, or on the order of, a physician. Learn more about servo compass in this new elearning program. Contact your maquet representative for more information. What measures help prevent accidental displacement of the balloon catheter during iabp. Evaluates pts neuro status assesses pt for signs of stroke cares for the patient with rhythm issues. The portfolio of maquet products is extensive, providing a comprehensive solution that is designed for efficient workflows, safety and the improvement of patient lives and outcomes. Advances in percutaneous ventricular assist devices. At longterm followup, what happens to patients with complications that exceeded the initial ones acta orthop scand 60. Do not perform manual inflation of the iab with the catheter extender tubing. The sensor balloon p2 is an advanced balloon with a builtin sensor. As the iabp inflates and deflates it allows an increase in.

Decreased urine output after the insertion of iabp can occur because of juxtarenal balloon positioning. Maquet is among the worlds leading vendors of forwardlooking medical technology for operating rooms and intensive care units. Intra aortic balloon counterpulsation learning package. Abiomed europe gmbh seyfarth 2008 or maquet cardiopul. Maquet believes that the modified flowi anaesthesia system ki 12114 is substantially equivalent to the cleared flowi anaesthesia system k102 182 and aisys k090233 regarding intended use of the devices, the indications for use and the fundamental technology of the devices. Maquet cardiovascular announces fda 510k clearance and. Comparison 1 iabp versus control, outcome 2 allcause mortality distribution. Digital variop creates a virtually futureproof integrated or thanks to the extensive modularity and flexibility that can be achieved through upgrades and reconfigurations. Maquet datascope cs300 service manual pdf download.

Maquet iii procedure, unloved due to its complications 2% to 59%, has been progressively abandoned. Maquet flowi c20 community, manuals and specifications. Optimal timing and function of iabp has the following features. Maquet specializes in solutions, therapies and products for surgical interventions, interventional cardiology and intensive care. Balloon diameter is increased by 2mmnylon catheter shaft performs high durability for better augmentation development of new concept balloon xemex iabp balloon plus 8f short balloon data attained by zeon experiment method. The technical data given in this publication is for general information and is subject to change without notice. Principles of intraaortic balloon pump counterpulsation. Whether surgical workplaces, cardiopulmonary or critical care maquet always puts the needs of staff and patients in the foreground during product development work. Osteotomy is performed with use of a thin oscillating saw blade 8 cm from the superior aspect of the tubercle distally in the coronal plane technique of maquet o. Intraaortic balloon pumps iabp a four hour powerpoint made by maquet, the makers of the pump and catheter, was designed for health care professionals with a sound understanding of hemodynamics who will be directly responsible for the care of patients requiring iabp therapy. Compare pay for popular roles and read about the teams worklife balance. The benefits of cardiohelp how can your patients benefit from an extracorporeal life support system. Designed for use with all current maquet intraaortic balloon catheters.

Correctly interprets patients heart rhythm correlates hr and rhythm with perfusion and coci intervenes as necessary in the following situations. It corresponds to various scenes with compact size and light weight. Take a quick interactive quiz on the concepts in intraaortic air balloon pumps. Usefulness of intraaortic balloon pump counterpulsation. Great idea to print and laminate and keep a copy with every balloon pump in your facility. Warnings, precautions and notes please read and adhere to the following list of warnings, precautions and notes. May 28, 2017 the intraaortic balloon pump iabp is a form of mechanical circulatory support used in cardiogenic shock, facilitating separation from cardiopulmonary bypass, percutaneous coronary interventions, unstable angina, and in thrombolytic therapy following a myocardial infarction. The program covers the historical, theoretical, and clinical considerations for patients receiving counterpulsation therapy. Intraaortic balloon counterpulsation therapy has been the firstline strategy for patients requiring mechanical circulatory support for more than 40 years. In addition to traditional high functions, it has a number of superior functions to assist operators. The primary goal of intraaortic balloon pump iabp treatment is to increase myocardial oxygen supply and decrease myocardial oxygen demand. By continuing to browse the site you are agreeing to our use of cookies.

Flowi comes in three models depending on your needs. Roofing most of the advice given previously on construction practice for decking, as this is now covered comprehensively in separate bcsa documents guide to the installation and installers of metal anchors on the requirements and prohibitions set out in the relevant loose material, regulation 43 in relation to construction of. Maquet balloon pump instruction poster free download as pdf file. Find out what works well at maquet cardiovascular from the people who know best. Discuss operation and troubleshooting of the maquet iabp. In 2010, maquet generated nearly half of the groups annual revenue of 2. For the fiscal year 2005 the getinge group posted sales revenues. Haemolysis from mechanical damage to red blood cells can reduce the haematocrit by up to 5%. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Maquet is a subsidiary of the publiclylisted swedish group of companies getinge ab. Manufacturer specifications cardiosave hybrid, maquet please note. Maquet cardiovascular announces fda 510k clearance and ce. Roofing most of the advice given previously on construction practice for decking, as this is now covered comprehensively in separate bcsa documents guide to the installation and installers of metal anchors on the requirements and prohibitions set out in the relevant loose material, regulation. The signal the iabp uses to identify the beginning of the next cardiac cycle.

Program code 06 please rate the program and speaker items by placing a mark in the appropriate column. Significantly quieter when compared to earlier generation maquet datascope iabps. Maquet cardiosave balloon pump maquet cardiosave iabp. A2 cardiothoracic unit orientation competency checklist. Community forums for maquet cardiosave iabp hybrid relating to maquet cardiosave balloon pump on medwrench. April 9, maquet cardiovascular usa announced publication of catascope manuscript comparing the clinical and economic for patients with certain heart conditions, the use of an intraaortic balloon pump is an effective way to help the heart do its work. Contact our sales representatives for a complete list of details. Uncover why maquet cardiovascular is the best company for you. Learn vocabulary, terms, and more with flashcards, games, and other study tools. The official maquest iabp poster for inserting their product. Iabp cardiovascular surgery products senko medical. The intraaortic balloon is placed within the descending aorta. The purpose of iabp is to increases the oxygen supply to allow the heart muscle to rest and improves perfusion to the coronary arteries.

Maquet the gold standard developments made in conjunction with doctors. The device is introduced from the femoral artery and guided into the. The experiment proved that xemex short iabp is superior to those of competitors as well as xemex conventional balloon. All models feature a rotatable arm for flexible screen positioning, tiltable screens to allow for maximized screen visibility and vertical and horizontal rails for auxiliary equipment. Intraaortic balloon pumps iabp this channel includes news and new technology innovations for i ntraaortic balloon pumps iabp. Make sure patient observes bed rest with hob at no more than 30 degrees, make sure patient avoids flexion of the involved hip. Mechanical circulatory support companion brochure getinge group. Iabp cardiothoracic critical care nursing education. Program evaluation 1 poor 2 fair 3 good 4 very good 5 excellent 1.

We retrospectively studied patients who were submitted to maquet iii procedure, by functional and radiologic longterm outcomes, in order to determine if this. Servo compass allows clinicians to visually assess patients at a glance for tidal volumes and peak pressures, alerting clinicians to changing conditions and allowing them to intervene with appropriate therapy. The intraaortic balloon pump iabp is a form of mechanical circulatory support used in cardiogenic shock, facilitating separation from cardiopulmonary bypass, percutaneous coronary interventions, unstable angina, and in thrombolytic therapy following a myocardial infarction. Cardiosave hybrid easily and quickly converts from hospital configuration to transport configuration. Red line represents actual pressure tracing with an initial systolic waveform followed by an pump generated waveform and then the systolic waveform seen following a balloon waveform with reduced systolic pressure. Close cooperation and many years of experience have resulted in tried and tested products which facilitate the work in the operat. K2829 page 2of 7 maquet cardiopulmonary ag premnarcet notification special 51 0k change due to recallcorrective action modified quadroxi.

We retrospectively studied patients who were submitted to maquet iii procedure, by functional and radiologic longterm. Please see appendix 2 on page 9 for a list of country specific fax numbers. No other percutaneous support device has proven superiority over iabps for treating patients with acute coronary syndrome and other complications of heart failure. Iabps are a type of hemodynamic support device that is inserted into the aorta to help the heart pump blood. Flowi is a product of maquets leadership in or and icu medical technology development. The theory and timing of balloon counterpulsation, factors affecting diastolic augmentation, indications, contraindications and potential complications are also discussed. Intraaortic balloon pump iabp counterpulsation is the most widely used mechanical circulatory support device because of its ease of use, low complication rate, and fast manner of insertion. Maquet ranks among the leading providers of medical products, therapies and services for surgical workplaces, critical care and cardiovascular applications.

The compact and portable cardiohelp system is ideal for the treatment of patients who require circulatory and or pulmonary support up to six hours. Since its foundation more than 170 years ago, maquet has stood for innovation and the advancement of patient care technologies in the field of medicine. Foreword introduction foreword this manual is intended to provide information required to properly service the datascope cs300 intraaortic balloon pump. For more than 40 years, maquet has been setting mechanical ventilation standards with the high performance servo platform. Manufacturer specifications cardiosave hybrid, maquet. Office of medical affairs atrium medical corporation 5 wentworth drive hudson, nh 03051 u. What to look for on iabp tracings ensure the timing is correct and the balloon waveform appears at the dicrotic notch what is the support ratio 1.

1202 1493 1283 955 988 774 1271 377 566 396 1226 417 206 1217 839 869 506 811 414 832 1055 483 1087 791 492 738 611 1303 359 1470